Product Overview
Centralized data processing for marine tank gauging systems
The Honeywell Communication Interface Unit acts as the central processing point for a vessel’s tank gauging system.
It collects measurement signals from onboard instruments such as radar gauges, pressure transmitters, temperature sensors and electropneumatic level transmitters, then processes this data for use by operators and connected ship systems.
This makes the unit especially useful on tankers and FPSO vessels where multiple tanks and measurement devices need to be monitored from one control-room interface.
Built for large marine monitoring systems
The system can handle measurement data from up to 64 cargo tanks and accept up to 96 additional instrument inputs, giving it the capacity needed for larger vessel installations.
Depending on the configuration, the interface can process:
- Tank level and ullage
- Temperature
- Pressure
- Corrected volume
- Mass
- Ballast level
- Trim and heel
- Atmospheric pressure
- On/off signals
The unit can then provide this data to marine tank gauging software, loading computers and other vessel systems.
Integration with Honeywell fixed gauging equipment
The Communication Interface Unit works as part of Honeywell’s wider marine fixed gauging architecture.
It can integrate with products such as:
- EM540 radar level gauges
- T901 temperature and pressure transmitters
- CT801 electropneumatic level transmitters
- PL3700X pressure transmitters
Together, these components can form a complete tank gauging solution for cargo, ballast and service tank monitoring.
Typical applications
- Cargo tank monitoring
- Ballast tank monitoring
- Service tank monitoring
- Tanker cargo measurement
- FPSO tank gauging
- Centralized vessel instrumentation
- Tank level, pressure and temperature monitoring
- Integration with loading computers
- Marine tank gauging control rooms
Key features
- Centralizes data from multiple marine instruments
- Supports up to 64 cargo tanks
- Accepts up to 96 additional instrument inputs
- Processes level, pressure and temperature data
- Supports trim and heel monitoring
- Calculates corrected volume and mass
- Integrates with loading computers and tank gauging software
- Supports Modbus RTU output
- Uses Honeywell EMS communication protocol
- Available for standard 19-inch rack installation
- Supports multiple analog and multifunction I/O boards
- Remote connectivity capability
- Safety rack version with IECEx and ATEX certification
Technical specifications
| Specification | Communication Interface Unit |
|---|---|
| Main units | TA3840C Communication Rack / TA3840S Safety Rack |
| Installation | Standard 19-inch rack |
| Rack sizes | 12U and 21U |
| Cargo tank capacity | Up to 64 tanks |
| Additional inputs | Up to 96 |
| Serial channels | 4 |
| Analog input capacity | Up to 48 channels |
| Monitored parameters | Level, ullage, temperature, pressure, corrected volume, mass, ballast level, trim, heel |
| Communication output | Modbus RTU |
| Internal protocol | EMS |
| Operating temperature | 5°C to +70°C |
| Hazardous-area certification | IECEx / ATEX for TA3840S safety unit |