Green Instruments G4130 NOx/O₂ Analyzing System

Green Instruments

(No reviews yet) Write a Review

For pricing contact: sales@neohance.tech

Product Overview

The Green Instruments G4130 NOx/O₂ Analyzing System is a reliable in-situ gas analysis solution designed for continuous monitoring of nitrogen oxides (NOx) and oxygen (O₂) concentrations in marine engine exhaust gases.

Using advanced zirconia sensor technology, the G4130 measures NOx and O₂ directly in the exhaust gas stream, providing real-time data to support combustion optimization, emissions monitoring and environmental compliance.

The system is particularly suitable for marine applications involving Selective Catalytic Reduction (SCR) and Exhaust Gas Recirculation (EGR), helping vessel operators monitor combustion performance and optimize operating parameters, including fuel combustion and urea injection.

Designed for demanding maritime environments, the G4130 combines an analyzer, analyzing board and diffusion probe. Its in-situ measurement technology eliminates the need for conventional sample lines, gas conditioning systems and converters, simplifying installation and reducing maintenance requirements.

An intuitive touchscreen interface, automatic probe backflushing and durable construction make the system a practical solution for reliable exhaust gas monitoring and efficient vessel operations.

Key Features

  • Continuous in-situ monitoring of NOx and O₂ concentrations in exhaust gases
  • Zirconia sensor technology for reliable wet-basis measurements
  • Real-time data supporting SCR and EGR optimization
  • Supports emissions monitoring and environmental compliance documentation
  • No conventional sample lines, gas conditioning systems or converters required
  • Automatic probe backflushing to remove soot and dust
  • Integrated touchscreen interface with trend graph display
  • Configurable analog output signals
  • Compact, robust design for demanding marine environments
  • Straightforward installation, integration and maintenance

 

Technical Specifications

  • Manufacturer: Green Instruments
  • Model: G4130
  • Measurement Principle: Zirconia-type sensor
  • NOx Measurement Range: 0–1,500 ppm
  • O₂ Measurement Range: 0–21%
  • Power Supply: 100–230 VAC, 50/60 Hz or 24 VDC
  • Power Consumption: 40 VA per analyzer
  • Ambient Temperature: 0–55°C
  • Analog Outputs: 2 × 4–20 mA, range selectable
  • Default Output Scaling: NOx: 0–2,000 ppm / O₂: 0–25%
  • Maximum Signal Load: 600 Ω at 24 VDC
  • Alarm Relays: Voltage-free, 24 VAC/DC, 5 A
  • Display: 71 × 39 mm touchscreen with trend graph
  • Analyzer Protection: IP67
  • Analyzer Dimensions: 170 × 200 × 90 mm
  • Analyzing Board Dimensions: 600 × 500 × 140 mm
  • Analyzing Board Weight: Approximately 10 kg
  • Diffusion Probe Temperature: 0–500°C
  • Diffusion Probe Insert Length: 208–338 mm
  • Suitable Duct Diameters: 235–2,800 mm
  • Calibration Gas Flow: Approximately 0.5–1 L/min
  • Diffusion Probe Weight: Approximately 6 kg
  • Umbilical Cord Length: 3 m

Technical specifications are subject to change without prior notice.

 