Product Overview
The Green Instruments G7000 Multi Gas Monitoring System is a robust and modular Continuous Emissions Monitoring System (CEMS) designed for accurate, real-time monitoring of exhaust gas emissions in marine applications.
The system continuously measures sulphur dioxide (SO₂) and carbon dioxide (CO₂) concentrations in exhaust gases, providing essential data for monitoring exhaust gas cleaning systems (EGCS) and supporting compliance with applicable IMO emissions requirements.
Using non-dispersive infrared (NDIR) measurement technology, the G7000 delivers reliable gas analysis under demanding marine operating conditions. Its modular design allows different gas configurations to be adapted to specific operational requirements.
The system features a gas sampling and conditioning arrangement designed to handle wet, acidic exhaust gases. Depending on the configuration, multiple sampling points can be connected to a single monitoring system.
With its robust construction, automatic calibration functions and integration capabilities, the G7000 supports continuous emissions monitoring, environmental reporting and efficient vessel operations.
Key Features
- Continuous monitoring of SO₂ and CO₂ concentrations
- Real-time SO₂/CO₂ ratio measurement
- NDIR gas measurement technology
- Suitable for marine exhaust gas cleaning systems
- Modular configuration for different monitoring requirements
- Multiple sampling points supported
- Designed for wet and acidic exhaust gas conditions
- Automatic zero and span calibration functions
- Modbus TCP/IP communication
- Robust construction for demanding marine environments
- Low maintenance requirements
Technical Specifications
- Manufacturer: Green Instruments
- Model: G7000
- System Type: Continuous Emissions Monitoring System (CEMS)
- Measurement Principle: Non-Dispersive Infrared (NDIR)
- Standard SO₂ Measurement Range: 0–200 ppm
- Standard CO₂ Measurement Range: 0–10%
- Optional SO₂ Measurement Range: 0–1,000 ppm
- Optional CO₂ Measurement Range: 0–20%
- Additional Gas Monitoring: Available depending on configuration
- Display: 7.5-inch TFT LCD colour touchscreen
- Communication: Modbus TCP/IP
- Alarm Outputs: 4 relays for system and measurement warnings/alarms
- Sampling Points: Up to 5 probes, depending on configuration
- Enclosure Protection: IP55
- Enclosure Material: Painted mild steel
- Gas Sample Flow: Approximately 0.33–1.67 L/min
- Ambient Operating Temperature: 5–45°C
- Gas Sample Conditioning: Integrated gas conditioning system
- Calibration: Automatic zero and span calibration
- Power Supply: Configuration-dependent; refer to electrical documentation
- Technical specifications are subject to change without prior notice.